The short answer

A rotary vacuum drum filter is a cloth-covered drum that turns slowly through a trough of slurry while a vacuum pump holds the inside of the drum below atmospheric pressure. On each revolution, the part of the drum under the slurry forms a cake, the part above it dewaters, washes and dries that cake, and a discharge device takes the cake off before the same surface dips back in. It runs continuously while the cake forms and discharges. We build rotary vacuum drum filters with precoat, scraper, string, belt and roller discharge.

Where it fits comes down to a limit that is easy to miss on a datasheet: the driving force can never exceed one atmosphere, and a hot filtrate takes part of that atmosphere away before filtration starts. A slurry that forms a cake quickly inside that limit suits a drum. One that needs more pressure, or a liquid close to its boiling point, points to a pressure filter. The rest of this article walks through one revolution, explains why published submergence figures disagree, and shows how to check the limit on your own duty.

One revolution, zone by zone

Micronics, which builds drum filters, describes the sequence plainly: "A horizontal drum floats in a vat into which process slurry is pumped. The drum rotates through then out of the slurry" (Micronics). Each point on the drum surface passes through the same zones on every turn.

  1. Cake formation. While a section is submerged, vacuum draws liquid through the filter medium and solids build up on it. An agitator in the trough keeps the solids in suspension so the cake forms evenly.

  2. Dewatering. As the section rises out of the slurry, the vacuum continues and pulls liquid out of the cake.

  3. Washing. Where the cake must be washed, sprays apply wash liquid to the cake surface. Micronics places this at about the 10 o'clock position, with further dewatering as the drum turns toward 12 o'clock.

  4. Drying. The vacuum keeps drawing air through the cake. In Micronics' words, "The cake now creates a pressure differential that dries the cake to low moistures."

  5. Discharge. The vacuum is released and the cake leaves the drum, by one of the methods described below.

Two parts do the control work. Inside the drum, the surface is divided into sections, each with its own filtrate pipes leading to a rotary valve at one end. The valve holds adjustable bridge blocks. Micronics calls this control the "timing" of the vacuum: the block positions set which sections are forming, which are drying, and, in some designs, where the vacuum is cut for discharge. Outside the drum, filtrate and air go to a vacuum receiver, where they separate. The air goes to the vacuum pump and the filtrate is pumped out from the bottom.

Two settings control the output: drum speed and vat level. Micronics states that "The production rate is directly determined by the drum speed (measured in "MPR" or minutes per revolution) and drum submergence (or vat level)." Wikipedia's summary of operating practice names the same two "basic operating parameters" (Wikipedia).

Why published submergence figures disagree

How much of the drum sits in the slurry is one of the first figures a buyer looks for, and the published answers do not agree.

  • Micronics: "the drum is commonly submerged from 10% up to 37.5% in the slurry."

  • Wikipedia: "approximately 50-80% of the screen area immersed in the slurry". The sentence carries no citation.

  • US Patent 4,618,424, a rotary vacuum filter with an adjustable trough, describes an immersion angle that "can be varied from about 160°" down "to about 20°-30°", and gives about 30° as common for wine must (US 4,618,424). In our arithmetic, 160° is about 44 percent of the circumference and 20 to 30° is about 6 to 8 percent.

So the published range runs from single figures to 80 percent. Part of the spread is a matter of basis: an angle of the circumference, a share of the screen area and a depth in the vat are not the same measure. But the larger reason is that submergence is not a property of the machine. It is a setting.

Micronics describes the trade-off: "High drum submergence will generally yield thick cakes. However, the moisture content may be high due to the shorter dry time. When low cake moisture is required, then the drum submergence is reduced to offer more dry time. But then the cake thickness will be low resulting in a lower production rate." The patent makes the same point from the other side: it exists because "conventional filters are made for filtering a certain type of suspension and lose capacity when filtering another suspension."

The patent's drum is "pre-coated with a layer of filtering aid". In our reading, that is why its figures run so low: on a precoat drum the solids layer removed each turn is thin, and most of the revolution can be spent outside the slurry. The useful question to ask a supplier is therefore not "what submergence does your drum have?" but "what form time and dry time does my slurry need, and what submergence and drum speed give me both?"

The one-atmosphere ceiling

A vacuum filter is pushed by the atmosphere. The pressure on the outside of the cake is atmospheric, the pressure inside the drum is lower, and the difference drives the liquid through. Wikipedia states the consequence: "the pressure difference is theoretically limited to atmospheric pressure (1 bar), and in practice somewhat lower." Standard atmospheric pressure is 101.3 kPa, and no vacuum pump can create a larger difference than that.

A pressure filter has no such ceiling, because the pressure is applied to the slurry side and is limited by the vessel design, not by the air outside. That is the basic reason a slow-filtering solid can be worth moving to a pressure filter. Micronics adds a caution that runs the other way: "High vacuum levels during cake formation increase cake thickness and yield. Compressible cakes, however, may have a high-pressure differential which will reduce the production rate." More driving force does not always mean more output.

Hot filtrate shrinks the ceiling

The second limit is the one that catches hot duties. Once the filtrate passes through the cloth, it is under vacuum all the way through the drum pipes, valve and receiver. If the pressure anywhere on that path falls to the vapour pressure of the liquid at its temperature, the liquid boils. That is what a saturation, or vapour, pressure is: the pressure at which the liquid boils at that temperature. In a plant, our reading is that boiling filtrate means vapour loading the vacuum pump and a falling vacuum in the drum.

For water, the saturation pressures are well established. The NIST Chemistry WebBook (NIST) and Engineering ToolBox (Engineering ToolBox) give the same values for the vapour pressure of water:

  • 60 °C: vapour pressure 19.9 kPa, so about 81 kPa of differential is left before the filtrate boils, roughly 80 percent of the ceiling.

  • 70 °C: 31.2 kPa, leaving about 70 kPa, roughly 69 percent.

  • 80 °C: 47.4 kPa, leaving about 54 kPa, roughly 53 percent.

  • 90 °C: 70.2 kPa, leaving about 31 kPa, roughly 31 percent.

The differentials are our arithmetic, taken from 101.3 kPa. These are upper bounds for pure water at sea-level standard pressure, before any loss in the pipes, valve and receiver. For any other liquor, use its own vapour pressure curve. That is why 911Metallurgist's leaf test procedure lists "vapour pressure variation with temperature" among the liquor data.

The practical rule follows. 911Metallurgist's guide to filter testing says that while vacuum filtration is used across mineral processing, "pressure filtration would be preferred where" the liquid "is very close to the boiling point" (911Metallurgist). The figures show why: at 90 °C, pure water leaves less than a third of the atmosphere to work with.

Where a drum fits, and where it does not

The same 911Metallurgist guide lists three cases where a pressure filter is preferred over a vacuum filter:

  • the liquid "is either too viscous";

  • the liquid "is very close to the boiling point";

  • the solids "are so fine and filter so poorly, or feed concentration is so low that a discharge cake cannot economically be formed, and a pre-coat filter cannot be considered for other reasons."

The third case contains the drum's own answer to fine or dilute solids: the precoat drum. WesTech says precoat discharge is "best applied to processes which have relatively low concentrations of solids or produce filter cakes which effectively blind the filter media" (WesTech). A layer of filter aid is built up on the drum first, and a knife shaves a thin cut from it on each revolution, taking the trapped solids with it.

Read the other way, and in our reading, the list sketches the drum's home ground: a liquid that is not too viscous and not near its boiling point, carrying solids that form a cake within the time the drum allows. Micronics positions its own drum as "a continuous filter for low-to-medium production rates with medium filterability". In those conditions, the drum offers continuous operation, washing on the drum itself and a cake that leaves without opening a vessel.

Two other points are worth weighing. First, the trough is open. A closed pressure vessel, such as a horizontal or vertical leaf filter, keeps the liquid enclosed while it filters. In our reading, a volatile or hazardous liquid is a reason to look at the closed vessel first. Second, Wikipedia notes that "The cake tends to crack due to their air drawn through by the vacuum system, so that washing and drying are not efficient", and that pressing the cake helps prevent cracking. If the cake must be washed thoroughly, test the wash on the real cake.

If the downstream step is a dryer, the filter's job is to remove as much water as the cake will give up first. We covered that trade in drum dryer vs spray dryer. For the choice between two pressure filters, see leaf filter vs filter press.

The five common discharge types, in one line each

The discharge is chosen to suit the cake, and the published descriptions agree on what each one is for. WesTech's summary:

  • Scraper: "The most common drum filter discharge." A blade directs the cake, loosened by an air blowback, into the chute.

  • Precoat: for low solids or cakes that blind the medium; a knife advances into the filter aid layer.

  • Roll: "Especially good for thin, sticky cakes which have the unique property of sticking to themselves."

  • String: for "thin cakes and materials that are unstable"; endless strings lift the cake off the drum.

  • Belt: the filter cloth leaves the drum, so both sides of the cloth are washed on every revolution.

We build all five. Which one suits a given cake is a question for the test, not for a table.

Sizing starts with a leaf test

Because submergence, drum speed and vacuum all move together, a drum is not sized from a datasheet. It is sized from a test on the real slurry. The leaf test is the usual method; 911Metallurgist describes it as representing "a small section of a continuous filter", and says that "when used with techniques properly simulating the continuous filter, it can give results adequate for sizing production filters and predicting performance or determining the need for pilot testing."

The procedure in that guide, in short:

  1. Take a representative sample, "generally 15-20 liters".

  2. Set the test vacuum, then submerge the leaf and start the timer for the planned form time.

  3. Lift the leaf out "just as a filter section" and dry it under vacuum for the planned dry time, noting "the time of any cake cracking".

  4. Measure the filtrate, the cake thickness, and the cake's wet and dry weights.

The guide adds that "The actual vacuum throughout a test should be controlled and observed since this is a major factor in performance and sizing." Its list of the slurry information needed includes temperature, viscosity and vapour pressure, which links straight back to the ceiling above. A leaf test run at room temperature on a liquor that runs hot in the plant tests a different machine.

What we build

We have manufactured and supplied rotary vacuum drum filters, and we build them with precoat, scraper, string, belt and roller discharge. About 1,000 units are installed worldwide across 460+ installations, in all applications, and most of those units are leaf filters. Each drum is sized to the duty. For an application new to us, we offer a trial filtration test before an order.

Send us your duty

The most useful enquiry gives us the slurry and its feed solids, the liquid and its operating temperature, its viscosity if known, whether the cake must be washed, how dry it must be, and how it must leave the filter. We will tell you whether a rotary vacuum drum filter fits your duty, which discharge suits the cake, or whether a pressure filter is the better choice. Contact our engineers.

CTA BG

Have a filtration duty you want checked?

CTA BG

Have a filtration duty you want checked?

CTA BG

Have a filtration duty you want checked?